Mostrar registro simples

dc.contributor.advisorAltafini, Carlos Roberto
dc.contributor.authorRech, Giovanni Matheus
dc.contributor.otherIndrusiak, Maria Luiza Sperb
dc.contributor.otherCosta, Carlos Alberto
dc.contributor.otherSuarez, Oscar Alfredo Garcia de
dc.date.accessioned2016-12-09T18:14:15Z
dc.date.available2016-12-09T18:14:15Z
dc.date.issued2016-12-09
dc.date.submitted2016-08-11
dc.identifier.urihttps://repositorio.ucs.br/handle/11338/1421
dc.descriptionO presente estudo consistiu em avaliar os parâmetros aerodinâmicos de um modelo de ônibus rodoviário, comparando os resultados obtidos de simulação computacional via CFD (Computational Fluid Dynamics) com aqueles obtidos na experimentação em túnel de vento. O ônibus estudado foi do tipo rodoviário de um fabricante local, modelo Paradiso 1200. O veículo foi modelado em um software CAD (SolidWorks®) em duas escalas: 1/42 e 1/24. Além disso, para obter a comparação com a literatura, foram analisados dois tamanhos diferentes de um modelo do corpo de Ahmed. Posteriormente, foram criadas as malhas com as geometrias 3D e realizados os testes computacionais no software ANSYS FLUENT® para os quatro modelos, com o intuito de identificar alguns parâmetros aerodinâmicos como o coeficiente de arrasto, coeficiente de pressão, entre outros. Para as análises com o corpo de Ahmed foram utilizados os modelos de turbulência Spalart – Allmaras, κ – ε Standard, κ – ε RNG, κ – ω Standard, κ – ω SST e SST. Para os modelos de ônibus foram simulados apenas o modelo κ – ε Standard. Para a realização dos experimentos foi empregado um túnel de vento de circuito aberto, onde foram realizados testes de distribuição de pressão e arrasto aerodinâmico, variando a altura do vão livre entre a mesa automobilística e a superfície inferior dos modelos. Nos ensaios dos modelos onde houve a variação da altura em relação à mesa automobilística, foi identificado um aumento de 4,5% no valor do coeficiente de arrasto (Cd) para o corpo de Ahmed menor e 6,1% para o ônibus em escala 1/42. Comparando-se os resultados obtidos nos ensaios experimentais com aqueles obtidos nas análises numéricas, também ocorreram variações no Cd para todos os modelos. Nos ensaios de pressão o coeficiente de pressão (Cp) foi praticamente o mesmo entre os valores obtidos na análise em CFD e os valores experimentais, para ambos os modelos. Foram também realizados ensaios de visualização usando tufts de lã distribuídos na superfície externa do modelo menor de Ahmed e do modelo maior do ônibus. Esses ensaios indicaram nitidamente as regiões de recirculação de ar nos modelos, o que em parte não foi possível observar na análise computacional. Diante disso, verifica-se que os resultados experimentais obtidos em túnel de vento ainda são os mais confiáveis e utilizados, apesar dos altos custos envolvidos na construção de modelos, na instrumentação de alta tecnologia hoje disponível, nos métodos de visualização e na energia consumida nos testes.pt_BR
dc.description.abstractThe present study was to evaluate the aerodynamic parameters of a road bus model by comparing the results of computer simulation via CFD (Computational Fluid Dynamics) with those obtained in experiments in a wind tunnel. The bus studied was a road type from a local manufacturer, Paradiso 1200 model. The vehicle was modeled on a CAD software (SolidWorks®) on two scales: 1/42 and 1/24. Furthermore, for comparison with the literature, we analyzed two different sizes of Ahmed body model. Thereafter, the meshes were created from 3D geometry and the computational tests performed with FLUENT® ANSYS software for the four models in order to identify some aerodynamic parameters such as the drag coefficient, pressure coefficient, among others. For analysis of Ahmed bodies, the turbulence models Spalart - Allmaras, κ - ε Standard, κ - ε RNG, κ - ω Standard, κ - ω SST and SST were used. For bus models, the turbulence model κ - ε Standard was only used. For the experiments we used an open circuit wind tunnel, where tests of pressure distribution and aerodynamic drag were performed, varying the height of the clearance between the automotive table and the bottom surface of the models. In the model tests, in which there were the height variation relative to the automotive table, an increase of 4.5% in the value of the drag coefficient (Cd) for the lower Ahmed body, and 6.1% for the bus 1/42 scale were identified. In pressure tests, the pressure coefficients (Cp) were almost the same between the values obtained from the CFD analysis and experimental values for both models. Visualization tests using wool tufts distributed on the outer surface of the smaller Ahmed model and the higher bus model were also performed. These tests clearly indicated the air recirculation regions in models, which in part was not observed in the computational analysis. Thus, it appears that the experimental results are in wind tunnel still the most reliable and used despite the high costs involved in the building models, in the high-tech instrumentation available today, in the visualization methods and in the energy consumed in the tests.en
dc.language.isoptpt_BR
dc.subjectAerodinâmicapt_BR
dc.subjectArrasto (Aerodinâmica)pt_BR
dc.subjectFluidodinâmica computacionalpt_BR
dc.subjectÔnibuspt_BR
dc.subjectTúneis aerodinâmicospt_BR
dc.subjectAerodynamicsen
dc.subjectDrag (Aerodynamics)en
dc.subjectComputational fluid dynamicsen
dc.subjectComputational fluid dynamicsen
dc.subjectRoad busen
dc.subjectWind tumelsen
dc.titleAnálise numérica e experimental do comportamento aerodinâmico da carroceria de um ônibus rodoviáriopt_BR
dc.typeDissertaçãopt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.advisor.latteshttp://lattes.cnpq.br/3077081419985976pt_BR
mtd2-br.author.lattesRECH, G. M.pt_BR
mtd2-br.program.namePrograma de Pós-Graduação em Engenharia Mecânicapt_BR
mtd2-br.contributor.coorientadorNabinger, Eduardo


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples