Mostrar registro simples

dc.contributor.advisorCorso, Leandro Luís
dc.contributor.authorVargas, Rogério Santos
dc.contributor.otherFalavigna, Asdrubal
dc.contributor.otherLuciano, Marcos Alexandre
dc.contributor.otherGamba, Thiago de Oliveira
dc.date.accessioned2022-09-15T12:58:21Z
dc.date.available2022-09-15T12:58:21Z
dc.date.issued2022-09-15
dc.date.submitted2022-07-25
dc.identifier.urihttps://repositorio.ucs.br/11338/10955
dc.descriptionO objetivo deste estudo foi avaliar, por meio de simulação computacional, a diferença de resistência mecânica entre dois modelos de placas, reta e onda , usadas na fixação de fratura do fêmur, submetendo ambas a uma carga axial estática progressiva. Existem critérios para se avaliar o limite de escoamento de um material: Tresca; Von Mises e Mohr-Coulomb. Neste estudo, foi utilizada a teoria do critério da tensão de Von-Mises por ser utilizada em testes de resistência a fadiga de materiais dúcteis, neste caso, aço inoxidável. Este critério, indica que o escoamento de um material sólido se inicia quando atinge um valor crítico de tensão. Os modelos foram construídos computacionalmente utilizando o software de modelamento 3D. Foi utilizado o método matemático de elementos finitos para avaliar a curva de tensão e a deformação, dois elementos considerados fundamentais para verificar o comportamento do metal durante a aplicação de tensão e o deslocamento das placas, para, assim, avaliar a resistência de cada um. Os resultados obtidos após a análise por elementos finitos demonstram que as placas não atingem o limite crítico para escoamento, porém, a placa reta absorve 10 vezes mais tensão em comparação com a onda. A placa onda permite concluir que há decomposição da força aplicada. Ambas as placas permanecem em regime elástico com carga até 1000 N. A carga equivale ao peso do corpo e da gravidade. Concluiu-se que a força axial aplicada no sentido caudal se decompõe em resultantes se comparada à placa reta, a qual absorve toda carga, podendo atingir o limite crítico para escoamento antes da placa onda. [resumo fornecido pelo autor]pt_BR
dc.description.abstractThe objective of this study was to evaluate, by means of computer simulation, the difference in mechanical strength between two plate models straight and wave used in femur fracture fixation, submitting both to a progressive static axial load. There are criteria to evaluate the yield strength of a material: Tresca, Von Mises and Mohr-Coulomb. In this study, the Von-Mises strain criterion theory was used because it is used in fatigue strength tests of ductile materials, in this case, stainless steel. This criterion, indicates that the yielding of a solid material begins when it reaches a critical stress value. The models were built computationally using 3D modeling software. The finite element mathematical method was used to evaluate the stress and strain curve, two elements considered fundamental to verify the behavior of the metal during the application of stress and the displacement of the plates, to thus evaluate the strength of each. The results obtained after the finite element analysis show that the plates do not reach the critical limit for yielding, but the straight plate absorbs 10 times more stress compared to the wave plate. The wave plate allows the conclusion that there is decomposition of the applied force. Both plates remain in the elastic regime with load up to 1000 N. The load is equivalent to the weight of the body and gravity. It was concluded that the axial force applied in the caudal direction decomposes into resulting ones compared to the straight plate, which absorbs all the load and may reach the critical limit for yielding before the wave plate. [resumo fornecido pelo autor]en
dc.language.isoenpt_BR
dc.language.isoespt_BR
dc.language.isoptpt_BR
dc.subjectFêmur - Fraturaspt_BR
dc.subjectMétodo dos elementos finitospt_BR
dc.subjectOrtopediapt_BR
dc.subjectFemur - Fracturesen
dc.subjectFinite element methoden
dc.subjectOrthodonticsen
dc.titleOs benefícios mecânicos da placa em onda em relação a reta em casos de fraturas femurais : um estudo com elementos infinitospt_BR
dc.typeDissertaçãopt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.advisor.latteshttp://lattes.cnpq.br/1361716190853238pt_BR
mtd2-br.author.lattesROGÉRIO SANTOS VARGASpt_BR
mtd2-br.program.nameMestrado Acadêmico em Ciências da Saúdept_BR
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR
local.data.embargo2023-03-01


Arquivos deste item

Thumbnail
Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples