dc.descriptionNa refrigeração industrial os sistemas de sobrealimentação de líquido são os mais eficientes. Isso se dá porque que ao longo do circuito do equipamento sempre tem líquido evaporando. Nas empresas, os projetistas devem procurar a maior taxa de transferência de calor de cada equipamento fabricado. Para facilitar esses cálculos de rendimento térmico são utilizados softwares comerciais para entender qual a configuração do equipamento possui melhor eficiência. Esse trabalho teve por objetivo compreender quais dados o software considera e se seus valores correspondem aos encontrados na literatura, comparando com os dados experimentais retirados do equipamento em operação. Para atingir esse objetivo foi calculado o coeficiente global de transferência de calor externo (U_e), onde é considerada a eficiência da aleta, eficiência global do aletado, a taxa de incrustação interna e externa, devido a depósito gradual que ocorre na superfície, podendo ser de ferrugem, óleo, uma série de coisas que acontecem durante o funcionamento do equipamento, os fatores de incrustações foram extraídos da norma TEMA (Tubular Exchanger Manufacturers Association). Para o coeficiente convectivo interno de transferência de calor foram utilizados às equações desenvolvidas por Kattaan, aonde o valor médio calculado foi de 9.409,90 W/m²K. O coeficiente convectivo externo foi utilizado às equações de Wang, que considera todos os dados do bloco aletado, a temperatura e umidade do ar na entrada do evaporador, com estes dados foi possível calcular o valor de 65,57 W/m²K, utilizando todos esses valores foi possível calcular o U_e com o valor de 22,10 W/m²K, calculado a diferença de temperatura média logarítmica no valor de 6,39 °C, a capacidade térmica do evaporador analiticamente ficou com 15,11 kW, o valor informado pelo software é de 15,90 kW, e o calculado experimentalmente ficou com 9,95 kW, os valores calculados são semelhantes aos informados pelo software, mostrando que essas equações desenvolvidas podem ser utilizadas para cálculos de desempenho térmico do evaporador. [resumo fornecido pelo autor]pt_BR
dc.description.abstractIn industrial refrigeration, liquid supercharging systems are the most efficient. This is because there is always liquid evaporating along the equipment circuit. In companies, designers should look for a higher heat transfer rate from each manufactured equipment. To facilitate these calculations of thermal efficiency, commercial software is used to determine which configuration of the equipment has the best efficiency. This work aimed to understand which data the software considerations and if their values correspond to those found in the literature, comparing with the experimental data taken from the equipment in operation. To achieve this goal, the global coefficient of external heat transfer (U_e) was corrected, where the fin efficiency, global fin efficiency, an internal and external fouling rate, due to a gradual deposit that occurs on the surface, is considered. be it rust, oil, a series of things that happen during the operation of the equipment, the fouling factors were extracted from the TEMA (Tubular Exchanger Manufacturers Association) standard. For the internal convective heat transfer coefficient, in the equations developed by Kattaan was used, where the updated average value was 9,409.90 W / m²K. The external convective coefficient was used to Wang's equations, which considers all data from the finned block, the temperature and humidity of the air at the evaporator inlet, with these data it was possible to calculate the value of 65.57 W / m²K, using all of these value it was possible to calculate the U_e with the value of 22.10 W / m²K, calculate the logarithmic average temperature difference in the value of 6.39 ° C, the thermal capacity of the evaporator was analytically 15.11 kW, the value entered by software is 15.90 kW, and the upgrade experimentally got 9.95 kW, similar calculated values given by the software, showing that these developed equations can be used for evaporator thermal performance calculations. [resumo fornecido pelo autor]pt_BR
dc.language.isoptpt_BR
dc.subjectEngenharia mecânicapt_BR
dc.subjectEvaporadorespt_BR
dc.subjectCalor - Transmissãopt_BR
dc.subjectRefrigeraçãopt_BR
dc.titleAnálise comparativa entre dados experimentais de operação de um evaporador com resultados obtidos via software comercialpt_BR
dc.typeMonografiapt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.program.nameBacharelado em Engenharia Mecânicapt_BR
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR