Show simple item record

dc.contributor.advisorSantos, Venina dos
dc.contributor.authorBiron, Dionisio da Silva
dc.contributor.otherBaldasso, Camila
dc.contributor.otherBergmann, Carlos Pérez
dc.contributor.otherRodrigues, Marco Antônio Siqueira
dc.contributor.otherCamassola, Marli
dc.date.accessioned2016-06-21T16:37:36Z
dc.date.available2016-06-21T16:37:36Z
dc.date.issued2016-06-21
dc.date.submitted2016-02-24
dc.identifier.urihttps://repositorio.ucs.br/handle/11338/1181
dc.descriptionA contaminação e o uso indevido da água, atrelados ao aumento da população tem gerado preocupação por parte da legislação, o que vem levando ao estudo de novas tecnologias que visam o tratamento, o reúso e a recuperação da qualidade da água. Devido ao baixo custo e a alta eficiência, a tecnologia por membranas tem dominado o mercado de purificação de água. O uso de membranas combinadas a agentes bactericidas (e.g. prata e cobre) tem recebido destaque. Neste trabalho, membranas cerâmicas comerciais tubulares, de alumina α e mulita (M1 e M2, respectivamente), impregnadas com nanopartículas de prata e cobre foram preparadas e caracterizadas com o objetivo de sua aplicação na desinfecção da água. As membranas comerciais foram caracterizadas por difração de raios X (DRX), microscopia eletrônica de varredura (MEV), espectroscopia de dispersão de energia (EDE), porosimetria por intrusão de mercúrio (PIM) e testes de permeabilidade e retenção de proteínas. As nanopartículas de prata e cobre foram obtidas a partir da dissolução de AgNO3 e de Cu(NO3)2∙3H2O em poli(álcool vinílico) (PVA) 5% (m/v) seguida da redução química dos íons de prata e cobre em partículas metálicas. As dispersões coloidais de prata e de cobre obtidas foram impregnadas nas membranas comerciais por dip-coating e posteriormente calcinadas a 600°C para remoção do PVA. Para avaliar a eficiência bactericida das membranas preparadas, foram realizados testes de microfiltração e zona de inibição, utilizando a Escherichia coli como microrganismo indicador. Como resultados, as membranas com prata e cobre apresentaram eficiências bactericidas entre 88,75 e 100% e zona de inibição entre 10 a 15 mm. Por outro lado, as membranas sem prata e cobre resultaram em baixas eficiências de retenção de bactérias, entre 40,32 e 73,78%, e não apresentaram zona de inibição. Os resultados obtidos nesse trabalho indicam que a impregnação de prata e cobre em membranas cerâmicas tubulares foi eficiente e proporcionou efeito bactericida as membranas cerâmicas comerciais. [resumo fornecido pelo autor]pt_BR
dc.description.abstractThe contamination and the improper use of water linked to the population growth have caused concern on the part of the legislation, which has been leading to the study of new technologies that aim the treatment, reuse and quality recovery of water. Due to the low cost and the high efficiency, the technology with membranes has dominated the water purification market. The use of membranes combined with antibacterial agents (e.g. silver and copper) has been highlighted. In this work, commercial tubular ceramic membranes, α alumina and mullite (M1 and M2 respectively), impregnated with silver and copper nanoparticles were prepared and characterized in order to be applied in water disinfection. The commercial membranes were characterized by X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), Mercury Intrusion Porosimetry (MIP) and tests of permeability and of protein retention. The silver and copper nanoparticles were obtained by dissolving AgNO3 and Cu(NO3)2∙3H2O, respectively, in poly(vinyl alcohol) (PVA) 5% (w/v) followed by the chemical reduction of silver and copper ions into metallic particles. Those colloidal dispersions obtained were impregnated in the commercial membranes by dip-coating and then, were calcined at 600 ° C to remove the PVA. To evaluate the bactericidal efficiency of the prepared membranes, tests of microfiltration and of zone of inhibition were performed using Escherichia coli as the microorganism indicator. As results, both silver and copper membranes showed bactericidal efficiencies between 88.75 and 100% and an inhibition zone between 10 and 15 mm. On the other hand, the membranes without silver and copper impregnation showed low efficiency of bacteria retention, between 40.32 and 73.78% and did not presented a zone of inhibition. The results of this study indicates that the impregnation of silver and copper in tubular ceramic membranes was efficient and provided bactericidal effect.[resumo fornecido pelo autor]en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPESpt_BR
dc.language.isoptpt_BR
dc.subjectÁguas residuais - Purificaçãopt_BR
dc.subjectMembranas filtrantespt_BR
dc.subjectNanotecnologiapt_BR
dc.subjectSewage - Purificationpt_BR
dc.subjectMembrane filterspt_BR
dc.subjectNanotechnologypt_BR
dc.titlePreparação e caracterização de membranas impregnadas com nanopartículas de prata e cobre e sua aplicação na desinfecção da águapt_BR
dc.typeDissertaçãopt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.advisor.latteshttp://lattes.cnpq.br/9772785745100071pt_BR
mtd2-br.author.lattesBIRON, D. S.pt_BR
mtd2-br.program.namePrograma de Pós-Graduação em Engenharia de Processos e Tecnologiaspt_BR
mtd2-br.contributor.coorientadorAndrade, Mara Zeni


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record