dc.description | Visando o aspecto da segurança estrutural nas edificações de grande porte ou com arquitetura esbelta como edifícios altos, pontes, galpões e coberturas o vento é levado como um dos principais fatores para a análise estrutural. Já os deslocamentos horizontais da estrutura, causados pelo vento ou mesmo pelo desaprumo, podem modificar a distribuição das cargas verticais, gerando novos esforços e deslocamentos na estrutura, chamados de efeitos de segunda ordem. Estes efeitos podem ser extremamente importantes e significativos em algumas estruturas já em outras, podem ser dispensados. Para avaliar a estabilidade global de edifícios de concreto armado de forma prática dois parâmetros são apresentados na NBR 6118:2014 o parâmetro α e o coeficiente yz, responsáveis por classificar as estruturas como sendo de nós fixos ou móveis e indicar se os efeitos de segunda ordem podem ou não ser desprezados. O estudo da ação do vento nas estruturas é de grande importância visto que o mal dimensionamento pode prejudicar a o estado limite de serviço (ELS) e a segurança num todo da edificação podendo ocasionar o colapso da mesma. O presente trabalho tratou de um estudo de caso em edificação de pequeno porte, onde foram analisados o parâmetro α, e os coeficientes yz, FAVt e RM2M1 que classificam a estabilidade da estrutura, bem como os momentos gerados pelo momento de desaprumo (Mig), e o momento causado pelo vento (M1). Essa análise foi realizada em dois modelos estruturais, um considerando uma junta de dilatação e outro que não possuía. Como resultados obteve-se os casos críticos na direção X da estrutura, com ventos a 0° e 90°, com os esforços de vento sendo superiores 4,2 e 5,6 vezes em relação ao desaprumo em todos os casos. E referente a estabilidade global da estrutura, todos os parâmetros analisados e comparados com norma indicam que a estrutura é classificada como sendo de nós fixos, bem como os deslocamentos horizontais e entre pisos que estão dentro do limite permitido pela norma. [resumo fornecido pelo autor] | pt_BR |
dc.description.abstract | Aiming at the aspect of structural safety in large buildings or buildings with slender architecture such as tall buildings, bridges, sheds and roofs, wind is taken as one of the main factors for structural analysis. On the other hand, horizontal displacements of the structure, caused by wind or even out of plumbness, can modify the distribution of vertical loads, generating new efforts and displacements in the structure, called second-order effects. These effects can be extremely important and significant in some structures while in others they can be dispensed with. In order to assess the global stability of reinforced concrete buildings in a practical way, two parameters are presented in NBR 6118:2014, the parameter α and the coefficient yz, responsible for classifying the structures as being with fixed or mobile nodes and indicating whether the second order effects may or may not be neglected. The study of wind action on structures is of great importance since poor design can impair the service limit state (SLS) and the safety of the building, which can lead to its collapse. The present work dealt with a case study in a small building, where the parameter α was analyzed, and the coefficients yz, FAVt and RM2M1 that classify the stability of the structure, as well as the moments generated by the out of plumb moment (Mig), and the moment caused by the wind (M1). This analysis was performed on two structural models, one considering an expansion joint and another that did not have one. As a result, the critical cases were obtained in the X direction of the structure, with winds at 0° and 90°, with the wind efforts being 4.2 and 5.6 times higher than the out of plumb position in all cases. And referring to the overall stability of the structure, all parameters analyzed and compared with the standard indicate that the structure is classified as being with fixed nodes, as well as the horizontal displacements and between floors that are within the limit allowed by the standard. [resumo fornecido pelo autor] | pt_BR |
dc.language.iso | pt | pt_BR |
dc.subject | Engenharia civil | pt_BR |
dc.subject | Análise estrutural (Engenharia) | pt_BR |
dc.subject | Edifícios - Estrutura | pt_BR |
dc.subject | Concreto armado | pt_BR |
dc.title | Ação do vento e do desaprumo: estudo de caso em uma edificação | pt_BR |
dc.type | Monografia | pt_BR |