Mostrar registro simples

dc.contributor.advisorReis, Juliana Tietbohl de Almeida
dc.contributor.authorTomazi, Joana Tomasine
dc.contributor.authorCosta, Paola
dc.contributor.otherMatuella, Letícia Grando
dc.contributor.otherVargas, Karlon Froes de
dc.date.accessioned2025-10-28T13:23:24Z
dc.date.available2025-10-28T13:23:24Z
dc.date.issued2025-10-17
dc.date.submitted2023-11-29
dc.identifier.urihttps://repositorio.ucs.br/11338/15071
dc.descriptionOs exames de imagem são amplamente utilizados na odontologia, tal como os exames radiográficos. Ao que diz respeito aos pacientes pediátricos, os exames radiográficos podem auxiliar em um diagnóstico mais preciso, bem como na elaboração de planos de tratamento. Um ponto negativo é que a dose de radiação, quando em excesso ou usada de forma inadequada, pode trazer prejuízos a alguns órgãos, como por exemplo a glândula tireoide. Objetivo: Avaliar através de RP, a discrepância de radiação ionizante na região posterior da glândula tireóide por meio de simuladores antropomórficos infantis. Metodologia: estudo aplicado em phantoms que simulam crianças de 6 e 11 anos de idade. Foram realizadas duas exposições em cada filme radiográfico, após foram processados e analisados em luxímetro no laboratório de física. Ambas etapas foram realizadas na Universidade de Caxias do Sul. Resultados: o protocolo panorâmico PP realizado no simulador antropomórfico de 11 anos foi o apresentou menor taxa de radiação. Como esperado, o phantom que teve maior dose recebida foi o de 6 anos, utilizando o protocolo G. Considerações finais: existem protocolos disponíveis que visam reduzir as doses de radiação em pacientes infantis durante a radiografia panorâmica. Cabe aos profissionais fazer o uso para garantir maior proteção às crianças, bem como aos seus órgãos sensíveis. [resumo fornecido pelos autores]pt_BR
dc.description.abstractImaging exams are widely used in dentistry, as are radiographic exams. With regard to pediatric patients, radiographic examinations can assist in a more accurate diagnosis, as well as in the development of treatment plans. A negative point is that the dose of radiation, when in excess or used inappropriately, can cause damage to some organs, such as the thyroid gland. Objective: to evaluate, through RP, the discrepancy of ionizing radiation in the posterior region of the thyroid gland using children's anthropomorphic simulators. Methodology: study applied to phantoms that simulate children aged 6 and 11 years old. Two exposures were made on each radiographic film, after which they were processed and analyzed using a lux meter in the physics laboratory. Both stages were carried out at the University of Caxias do Sul. Results: the PP panoramic protocol performed on the 11-year-old anthropomorphic simulator had the lowest radiation rate. As expected, the phantom that had the highest dose received was the 6-year-old, using protocol G. Final considerations: there are protocols available that aim to reduce radiation doses in child patients during panoramic radiography. It is up to professionals to use it to ensure greater protection for children, as well as their sensitive organs. [resumo fornecido pelos autores]pt_BR
dc.language.isoptpt_BR
dc.subjectOdontologia pediátricapt_BR
dc.subjectDentes - Radiografiapt_BR
dc.subjectDiagnóstico por imagempt_BR
dc.subjectRadiação - Testespt_BR
dc.titleDiscrepância da dose de radiação em face posterior da glândula tireoide em protocolos panorâmicos: um estudo em phantomspt_BR
dc.typeMonografiapt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.program.nameBacharelado em Odontologiapt_BR
mtd2-br.contributor.coorientadorVanni, Jessica Silvestre
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR
local.data.embargo2025-10-27


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples