dc.description | Este trabalho tem como objetivo preparar e avaliar membranas de Paládio em suporte cerâmico poroso de α-alumina, sinterizado a 1600ºC, utilizando os métodos sol-gel e de deposição química, electroless plating. Foram preparadas membranas, α-alumina/Pd, com uma e duas camadas de paládio na superfície externa do suporte cerâmico. O suporte cerâmico e as membranas foram caracterizados por análise morfológica através de Microscopia Eletrônica de Varredura (MEV), Espectroscopia por Dispersão de Energia (EDS), Porosimetria por Intrusão de Mercúrio e, a permeabilidade e seletividade dos gases H2, CH4 e CO2 a partir de um sistema de bancada. As imagens de MEV mostram uma superfície mais uniforme para a membrana com uma camada de paládio do que com duas camadas. Os testes de permeação de gases indicam que as membranas são seletivas, apresentando seletividade de ≈60% para H2/CO2 e ≈ 45% para H2/CH4 independente da espessura da camada de paládio depositada no suporte cerâmico. | pt_BR |
dc.description.abstract | This work aims to prepare and evaluate Palladium membranes on porous ceramic support of α-alumina, sintered at 1600ºC, using sol-gel and electroless plating technique. It were prepared membranes Pd/α-alumina, with one e two depositions of Pd in the external surface of ceramic support. The ceramic support and the membranes were characterized by morphological analysis through Scanning Electron Microscopy (SEM), Energy Dispersion Spectroscopy (EDS), mercury porosimetry and, the permeability and selectivity to H2, CH4 e CO2 from a bench system. The SEM images show that surface membrane is more uniform with one layer than two Pd layers. Gas permeability test suggest that the composite membranes possessed gas selectivity, and selectivity was of ≈60% for H2/CO2 gas and ≈45% for H2/CH4 gas, regardless of thickness of Pd layer. | pt_BR |
dc.language.iso | pt | pt_BR |
dc.subject | Membranas (Tecnologia) | pt_BR |
dc.subject | Permeabilidade | pt_BR |
dc.subject | Ciência dos materiais | pt_BR |
dc.subject | Cerâmica (Tecnologia) | pt_BR |
dc.subject | Membranes (Technology) | pt_BR |
dc.subject | Permeability | pt_BR |
dc.subject | Materials science | pt_BR |
dc.subject | Ceramics | pt_BR |
dc.title | Avaliação de membranas compósitas de Alumina-Pd na separação de gases | pt_BR |
dc.type | Dissertação | pt_BR |
mtd2-br.advisor.instituation | Universidade de Caxias do Sul | pt_BR |
mtd2-br.advisor.lattes | http://lattes.cnpq.br/6891977779777074 | pt_BR |
mtd2-br.author.lattes | BERTOTTO, Raphael | pt_BR |
mtd2-br.program.name | Programa de Pós-Graduação em Engenharia de Processos e Tecnologias | pt_BR |
mtd2-br.contributor.coorientador | Santos, Venina dos |