Mostrar el registro sencillo del ítem

dc.contributor.advisorMichels, Alexandre Fassini
dc.contributor.authorReinheimer, Letícia
dc.contributor.otherNabinger, Eduardo
dc.contributor.otherMissell, Frank Patrick
dc.contributor.otherPereira, Marcelo
dc.date.accessioned2015-05-11T18:45:09Z
dc.date.available2015-05-11T18:45:09Z
dc.date.issued2015-05-11
dc.date.submitted2014-11-04
dc.identifier.urihttps://repositorio.ucs.br/handle/11338/940
dc.descriptionEfetuou-se, de forma inédita, a avaliação da viscosidade de dois óleos Newtonianos em velocidades distintas de escoamento (1000rpm e 1500rpm) e em função da temperatura (24ºC a 50ºC), através de um método de reologia a laser, que consiste num interferômetro óptico acoplado a um spinner. Para a obtenção dos dados experimentais desenvolveu-se um sistema de aquecimento, o qual foi acoplado ao spinner, garantindo assim a estabilidade térmica durante o processo. Os dados experimentais obtidos através do método de reologia a laser corroboraram com o modelo de Emslie, Bonner e Peck (EBP), considerando que o modelo do coeficiente de determinação múltipla (R²) para o ajuste linear dos dados manteve-se muito próximo a 1. Já em comparação com o método tradicional, que utiliza a imersão de um spindle dentro de um Becker com fluído, e, dentro das incertezas experimentais, obteve-se boa concordância dos dados. Além disso, encontrou-se boa concordância com o modelo de Arrhenius que descreve o comportamento da viscosidade de fluídos em função da temperatura.pt_BR
dc.description.abstractThe viscosity assessment of two Newtonian oil was done in an unprecedented way in different flow speeds (1000rpm e 1500rpm), and as temperature function (24ºC to 50ºC), through a laser rheology method, which consists of an optical interferometer coupled to a spinner. To obtain the experimental data, a heatingsystem was developed, which was coupled to the spinner, thus ensuring the thermal stability during the process. The experimental data obtained through rheology laser method corroborated with the Emslie, Bonner e Parker (EBP) model, in which the coefficient of multiple determination, R² for a linear adjustment was close to 1. Therefore, in comparison to the traditional method and within the experimental uncertainty great data concordance was obtained. Also, great data concordance was found with the Arrhenius model, which describes the behavior of fluids viscosity due to the temperature.en
dc.language.isoptpt_BR
dc.subjectReologiapt_BR
dc.subjectViscosidadept_BR
dc.subjectMecânica dos fluidospt_BR
dc.subjectRheologyen
dc.subjectViscosityen
dc.subjectFluid mechanicsen
dc.titleMedição da viscosidade de óleos newtonianos por reômetro óptico em diferentes temperaturaspt_BR
dc.typeDissertaçãopt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.advisor.latteshttp://lattes.cnpq.br/2440040127454667pt_BR
mtd2-br.author.lattesREINHEIMER, L.pt_BR
mtd2-br.program.namePrograma de Pós-Graduação em Engenharia Mecânicapt_BR


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem