Show simple item record

dc.contributor.advisorGamba, Thiago de Oliveira
dc.contributor.authorMarí, Jéssica
dc.contributor.authorKarkow, Lissany Zanandréa Baldessar
dc.contributor.otherMattuella, Letícia Grando
dc.contributor.otherAbrão, Luciana Benfica
dc.date.accessioned2022-02-09T16:10:10Z
dc.date.available2022-02-09T16:10:10Z
dc.date.issued2021-12-18
dc.date.submitted2021-12-06
dc.identifier.urihttps://repositorio.ucs.br/11338/9487
dc.descriptionExames de imagem são amplamente utilizados pelos cirurgiões-dentistas como um exame complementar ao exame clínico, desta forma as radiografias convencionais podem ser implementadas a um custo relativamente baixo e com natureza de imagens bidimensional sendo utilizadas para diagnóstico de cárie, fraturas e doenças periodontais em primeiro momento, contudo as radiografias bidimensionais apresentam algumas limitações principalmente devido à sobreposição de estruturas, requerendo um exame mais confiável para avaliação de fraturas, assim como na implantodontia. Desta forma, Tomografia Computadorizada de feixe cônico é um exame complementar com alta acurácia, mas que deve ser solicitado seguindo as orientações do princípio ALARA "Tão baixo quanto razoavelmente exequível". Portanto, o presente estudo teve como objetivo identificar o melhor protocolo de qualidade de imagem utilizando a menor dose possível, para a visualização do canal incisivo e forame incisivo, utilizando cinco campos de visão, field of view (FOVs) diferentes e quatro voxels em um protocolo e três nos demais para a obtenção da seleção dos melhores protocolos para visualização. Para tal, foram avaliadas 32 imagens da cabeça de um cadáver humano, obtida no Departamento de Anatomia da Universidade de Caxias do Sul. Todas as tomografias foram realizadas na clínica de Radiologia Odontológica da Universidade de Caxias do Sul. Após avaliação da imagens de Tomografia Computadorizada de feixe cônico foram selecionados os melhores protocolos do aparelho OP300 maxio: FOV 5x5, V3 com filtro e V4 com e sem filtro; FOV 6x8, V2 com filtro e V3 com e sem filtro; FOV 8x8, V2 com filtro e V3 com e sem filtro, FOV 8x15, V2 com filtro e V3 com e sem filtro e por fim, FOV 13x15 em sua maioria apresentaram a qualidade de imagens insatisfatória. [resumo fornecido pelo autor]pt_BR
dc.description.abstractImaging exams are widely used by dentists as a complementary exam to the clinical exam, thus conventional radiographs can be implemented at a relatively low cost and with a two-dimensional image nature being used for the diagnosis of caries, fractures and periodontal diseases in the first place. Currently, however, two-dimensional radiographs have some limitations, mainly due to the overlapping of structures, requiring a more reliable examination to assess fractures, as well as in implant dentistry. Therefore, cone beam Computed Tomography is a complementary exam with high accuracy, but it must be requested following the guidelines of the ALARA principle "As low as reasonably achievable". Therefore, the present study aimed to identify the best image quality protocol using the lowest possible dose, for the visualization of the incisor canal and incisive foramen, using five different fields of view, field of view (FOVs) and four voxels in one protocol and three in the others to obtain the selection of the best protocols for visualization. To this end, 32 images of the head of a human cadaver, obtained at the Department of Anatomy, University of Caxias do Sul, were evaluated. All CT scans were performed at the Dental Radiology Clinic of the University of Caxias do Sul. of conical beam, the best protocols of the OP300 maxio device were selected: FOV 5x5, V3 with filter and V4 with and without filter; FOV 6x8, V2 with filter and V3 with and without filter; FOV 8x8, V2 with filter and V3 with and without filter, FOV 8x15, V2 with filter and V3 with and without filter and finally, FOV 13x15 mostly presented unsatisfactory image quality. [resumo fornecido pelo autor]pt_BR
dc.language.isoptpt_BR
dc.subjectOdontologiapt_BR
dc.subjectDentes - Radiografiapt_BR
dc.subjectTomografia computadorizada de feixe cônicopt_BR
dc.titleAnálise da qualidade de imagem do canal incisivo e forame incisivo por meio da utilização de diferentes protocolos de aquisição de imagens de tomografia computadorizada de feixe cônicopt_BR
dc.typeMonografiapt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.program.nameBacharelado em Odontologiapt_BR
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR
local.data.embargo2022-08-01


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record