Mostrar registro simples

dc.contributor.advisorMorales, Andréa Cantarelli
dc.contributor.authorFoletto, Matheus Augusto
dc.contributor.otherSevero, Tiago Cassol
dc.contributor.otherGiacomelli, Patricia
dc.date.accessioned2022-11-07T15:20:38Z
dc.date.available2022-11-07T15:20:38Z
dc.date.issued2021-12-16
dc.date.submitted2021-12-03
dc.identifier.urihttps://repositorio.ucs.br/11338/11133
dc.descriptionEste trabalho tem como objetivo apresentar um estudo de eficiência energética, que trata do gerenciamento e melhor aproveitamento do consumo e gastos com energia elétrica, para um posto de combustível estabelecido em Caxias do Sul, que tem funcionamento 24 horas por dia e tem a utilização de um compressor de ar para abastecimento de GNV (Gás Natural Veicular). O estabelecimento tem como classificação a tarifa Verde - A4 Comercial Atacadista e demanda contratada única de 130kW. Tendo em vista o elevado consumo de energia elétrica do estabelecimento, foi analisado e avaliado a realização da caracterização do padrão de consumo mensal de cada equipamento ligado à rede, buscando encontrar meios de mitigação e consequentemente a economia de recursos gastos com energia elétrica através da troca dos motores IR2 atuais por IR3 Premium. Além, foi avaliada a instalação de gerações independentes como placas de energia solar e ainda a utilização de gerador a diesel ou GNV para os horários de pico, que proporcionalmente são os horários mais onerosos para o estabelecimento. Após análise financeira das ações avaliadas, foi considerado que todas seriam benéficas na economia gerada, e que trariam retorno financeiro após um período determinado. [resumo fornecido pelo autor]pt_BR
dc.description.abstractThis paper aims to present a study about energy efficiency in a 24/7 gas station established in Caxias do Sul which has the use of a compressor for CNG (Compressed Natural Gas) supply. The establishment is A4 Green rated and commercial wholesaler classed. It also has a single contracted demand of 130Kw. In this article, we deal with the management and better use of electricity. We evaluate and analyze all electricity consumption levels and, based in that, we carried out monthly characterizations of the patterns of each equipment connected to the network, seeking to find ways to mitigate losses and consequently save related resources by exchanging current IR2 engines for IR3 Premium. In addition, this study will evaluate the possibility of installing an independent generator, either with solar energy plates or using a diesel and CNG generator for rush hours, which proportionally are the most costly schedules for the establishment. After the financial analysis of the evaluated actions, it was considered that they would all be beneficial in the generated savings, and that they would bring a financial return after a determined period. [resumo fornecido pelo autor]pt_BR
dc.language.isoptpt_BR
dc.subjectEngenharia elétricapt_BR
dc.subjectEnergia elétrica - Consumopt_BR
dc.subjectGeração distribuída de energia elétricapt_BR
dc.titleProjeto e análise de eficiência energética de posto de combustívelpt_BR
dc.typeMonografiapt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.program.nameBacharelado em Engenharia Elétricapt_BR
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples