dc.descriptionO concreto é o material mais utilizado no ramo da construção civil, podendo ser utilizado nas estruturas mais diversas, tais como pontes, rodovias, edificações, entre outros. Porém, para manter a vida útil e segurança dessas estruturas, torna-se necessários fazer manutenções periódicas que podem apresentar um custo bem elevado, podendo ser superior a uma construção nova. Uma estratégia que vem sendo estudada com o intuito de diminuir o intervalo dessas manutenções é o concreto autocicatrizante, que tem como intuito fechar as fissuras logo após a sua abertura, evitando a criação de grandes fendas e a entrada de agentes agressivos. Nesse trabalho, foi utilizado o método de autocicatrização autógena a partir da substituição parcial do cimento CP V ARI por escória alto-forno nas proporções de 25% e 50%. Diferentes relações água/cimento variando entre 0,30, 0,40 e 0,50 também foram avaliadas. Os corpos de prova cilíndricos foram pré-fissurados após 7 dias aplicando esforços de compressão correspondentes à 90% da carga de rompimento. Além disso, passaram pelos ensaios de resistência à compressão, absorção de água por capilaridade e microscopia óptica aos 28 e 63 dias. As amostras com menor relação água/cimento apresentaram os melhores resultados em relação à resistência à compressão. Além disso, as amostras sem substituição do cimento por escória apresentaram valores mais elevados de resistência à compressão quando comparado com as demais. Em relação aos ensaios de absorção de água por capilaridade, a absorção foi maior aos 63 dias quando comparado aos 28 dias. Já no ensaio de microscopia óptica, foi possível observar o início da autocicatrização das fissuras mais evidente nas amostras com relação água/cimento de 0,30. Porém todas as amostras analisadas apresentaram evidências do início do processo ao cicatrizante na análise de microscopia eletrônica de varredura. [resumo fornecido pelo autor]pt_BR
dc.description.abstractConcrete is the most used material in the construction industry, and can be used in the most diverse structures, such as bridges, highways, buildings, among others. However, to maintain the useful life and safety of these structures, it is necessary to carry out periodic maintenance, which can present a very high cost, which may be higher than a new construction. A strategy that has been studied in order to reduce the interval for these maintenances is self-healing concrete, which aims to close cracks right after they are opened, preventing the creation of large cracks and the entry of aggressive agents. In this work, the autogenous self-healing method was used from the partial replacement of CP V ARI cement by blast furnace slag in proportions of 25% and 50%. Different water/cement ratios ranging between 0.30, 0.40 and 0.50 were also evaluated. The cylindrical specimens were pre-cracked after 7 days, applying compression forces corresponding to 90% of the breaking load. In addition, they underwent compressive strength, capillary water absorption and optical microscopy tests at 28 and 63 days. The samples with the lowest water/cement ratio showed the best results in relation to compressive strength. In addition, the samples without cement replacement by slag showed higher values of compressive strength when compared to the others. Regarding the capillary water absorption tests, the absorption was greater at 63 days when compared to 28 days. In the optical microscopy test, it was possible to observe the beginning of the self-healing of the cracks more evident in samples with a water/cement ratio of 0.30. However, all analyzed samples showed evidence of the beginning of the healing process in the scanning electron microscopy analysis. [resumo fornecido pelo autor]pt_BR
dc.language.isoptpt_BR
dc.subjectEngenharia civilpt_BR
dc.subjectMateriais de construçãopt_BR
dc.subjectResistência de materiaispt_BR
dc.subjectConcreto - Deterioraçãopt_BR
dc.titleEstudo do uso de escória alto-forno no efeito autocicatrizante em concretospt_BR
dc.typeMonografiapt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.program.nameBacharelado em Engenharia Civilpt_BR
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR