Show simple item record

dc.contributor.advisorSilva, Gustavo Ribeiro da
dc.contributor.authorFerreira, Maikel William
dc.contributor.otherZatti, Luciano
dc.contributor.otherAlmeron, Maurício Monteiro
dc.date.accessioned2025-10-16T19:26:51Z
dc.date.available2025-10-16T19:26:51Z
dc.date.issued2025-09-08
dc.date.submitted2025-07-09
dc.identifier.urihttps://repositorio.ucs.br/11338/15034
dc.descriptionEste trabalho tem como tema central a análise da resistência à punção em lajes lisas de concreto armado, comparando os critérios normativos da ABNT NBR 6118:2023 e do Eurocode 2:2023. A punção é um fenômeno crítico no dimensionamento estrutural, caracterizado por uma ruptura frágil e localizada na interface entre a laje e o pilar, podendo comprometer a estabilidade global da estrutura. As lajes lisas, apesar de suas vantagens arquitetônicas e econômicas, são especialmente suscetíveis a esse tipo de falha, exigindo atenção rigorosa durante o projeto. As normas analisadas apresentam abordagens distintas: a ABNT NBR 6118 adota uma formulação empírica baseada na resistência à compressão do concreto, enquanto o Eurocode 2 utiliza uma abordagem mecânica fundamentada na teoria da fissura crítica de cisalhamento, proposta por Muttoni. Para avaliar o impacto dessas diferenças no desempenho estrutural, foi desenvolvido um estudo de caso com base no modelo proposto por Santos (2018) e ampliado por Silva (2022), utilizando modelagem computacional no software TQS®. A estrutura analisada é composta por lajes quadradas com diferentes espessuras (20, 30 e 40 cm), submetidas a três níveis de carga variável (1,5; 3,0 e 6,0 kN/m²). Foram definidos nove modelos estruturais, e as cargas solicitantes e taxas de armadura foram extraídas a partir da modelagem no TQS®. Os cálculos de verificação à punção foram realizados segundo os critérios de ambas as normas, considerando as respectivas superfícies de controle. Os resultados obtidos demonstram diferenças significativas entre as relações tensão resistente e tensão solicitante. Enquanto a ABNT NBR 6118:2023 apresentou relações tensão resistente/tensão solicitante superiores, atendendo aos critérios de segurança sem necessidade de armadura de punção em diversos casos, o Eurocode 2 exigiu reforço em todas as situações analisadas, refletindo em maior grau de conservadorismo. A diferença percentual entre a relação resistência e solicitação entre as normas superou 10% em todos os modelos, influenciada pela espessura da laje, pelo nível de carregamento e pela metodologia de cada norma. Conclui-se que ambas as normas são eficazes, porém com filosofias distintas de projeto: a norma brasileira é mais flexível, enquanto a europeia é mais conservadora, impondo margens adicionais de segurança. [resumo fornecido pelo autor]pt_BR
dc.description.abstractThis study focuses on the analysis of punching shear resistance in flat reinforced concrete slabs, comparing the design criteria established by ABNT NBR 6118:2023 and Eurocode 2:2023. Punching is a critical phenomenon in structural design, characterized by a brittle and localized failure at the slab-column interface, which can compromise the overall stability of the structure. Although flat slabs offer architectural and economic advantages, they are especially vulnerable to this type of failure, requiring rigorous attention during the design process.The analyzed standards present distinct approaches: ABNT NBR 6118 adopts an empirical formulation based primarily on concrete compressive strength, while Eurocode 2 uses a mechanical approach grounded in the Critical Shear Crack Theory (CSCT), as proposed by Muttoni. To evaluate the impact of these methodological differences on structural performance, a case study was conducted based on the model proposed by Santos (2018) and extended by Silva (2022), using computational modeling in the TQS® software. The analyzed structure consists of square slabs with varying thicknesses (20, 30, and 40 cm), subjected to three levels of live load (1.5, 3.0, and 6.0 kN/m²). Nine structural models were defined, and the internal forces and reinforcement ratios were obtained from the TQS® simulations. Punching shear verification was performed according to each standard?s criteria, considering their respective critical control surfaces.The results show significant differences in the ratios between punching shear resistance and applied shear stress. While ABNT NBR 6118:2023 yielded higher resistance-to demand ratios, often eliminating the need for punching reinforcement, Eurocode 2 required reinforcement in all evaluated cases, indicating a more conservative approach. The percentage difference between the standards' resistance-to-demand ratios exceeded 10% across all models, influenced by slab thickness, load level, and each standard's methodological basis.It is concluded that both standards are effective but adopt different design philosophies: the Brazilian standard is more flexible, while the European standard is more conservative, imposing additional safety margins. [resumo fornecido pelo autor]pt_BR
dc.language.isoenpt_BR
dc.language.isoptpt_BR
dc.subjectLajespt_BR
dc.subjectEngenharia Civilpt_BR
dc.titleAvaliação da diferença de resistência à punição sob a metodologia da ABNT NBR 6118:2023 e do Eurocode 2 (2023)pt_BR
dc.typeMonografiapt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.program.nameEngenharia Civil - Bachareladopt_BR
mtd2-br.campusCampus Universitário da Região dos Vinhedospt_BR
local.data.embargo2025-09-08


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record