Mostrar registro simples

dc.contributor.advisorFigueroa, Carlos Alejandro
dc.contributor.authorTomiello, Stevan Scussel
dc.contributor.otherAlvarez, Fernando
dc.contributor.otherAmorim, Cíntia Lugnani Gomes de
dc.contributor.otherFarias, Maria Cristina More
dc.date.accessioned2014-06-24T11:57:01Z
dc.date.available2014-06-24T11:57:01Z
dc.date.issued2014-06-24
dc.date.submitted2012-08-31
dc.identifier.urihttps://repositorio.ucs.br/handle/11338/718
dc.descriptionO presente trabalho apresenta um estudo para viabilizar a aplicação do tratamento duplex de nitretação e pós-oxidação a plasma como forma de incrementar a resistência à corrosão de aços-carbono. A influência da microestrutura, distribuição de fases cristalinas e composição química no comportamento à corrosão do material foram avaliadas, e o papel do teor de inclusões foi analisado. O estudo das fases cristalinas presentes foi realizado pela técnica de difração de raios X (DRX). A morfologia e a espessura das camadas foram avaliadas por microscopia eletrônica por varredura (MEV). As análises da composição química na superfície e em seção transversal foram determinadas por espectroscopia de descarga luminescente de emissão ótica (GD-OES) e espectroscopia de raios X por dispersão em energia (EDS). Duas técnicas complementares de avaliação da resistência à corrosão, polarização potenciodinâmica cíclica (PPC) e névoa salina foram realizadas, sendo que a segunda é a técnica utilizada como referência pela indústria. O tratamento de pós-oxidação formou apenas a fase magnetita, desejável por possuir melhores propriedades mecânicas frente a hematita. Parâmetros de 90 min a 480°C de pós-oxidação apresentaram as melhores características da camada externa de óxidos em termos microestruturais devido à alta homogeneidade e ausência de defeitos. Os ensaios de PPC corroboraram que este tipo de microestrutura apresenta a maior resistência à corrosão. Em névoa salina não houve reprodutibilidade de resultados, e novas análises indicaram a presença de inclusões de sulfeto de manganês (MnS) danificando a camada oxidada. Calculou-se o nível de severidade das amostras seguindo a norma ASTM E-45 e esse valor foi relacionado com o tempo de resistência à corrosão no ensaio de névoa salina. Se o nível de severidade do aço 1045 for menor que 2, pode-se substituir a aplicação de cromo-duro industrial pelo processo de nitretação ept_BR
dc.description.abstractThis paper presents a study to facilitate the application of duplex treatment of nitriding and post oxidation plasma as a way of enhancing the corrosion resistance of carbon steel. The influence of microstructure, phase distribution and chemical composition of crystalline corrosion behavior of the material were evaluated, and the role of inclusions content was analyzed. The study of the crystalline phases present was determined by means of X-ray diffraction (XRD). The morphology and thickness of the layers was evaluated by scanning electron microscopy (SEM). Analyzes of chemical composition on the surface and cross section were determined by spectroscopy of glow discharge optical emission (GD-OES) spectroscopy and X-ray energy dispersive (EDS). Two complementary techniques for evaluation of corrosion resistance, cyclic potentiodynamic polarization (CPP) and salt spray were performed, being the second is the technique used by the industry for reference. The treatment of post-oxidation was formed only the stage magnetite desirable to have improved mechanical properties compared to hematite. Parameters for 90 minutes at 480°C of post-oxidation provided the best characteristics of the outer layer in terms of oxide microstructural uniformity and high due to the absence of defects. PPC Tests corroborate this type of microstructure has the highest corrosion resistance. In salt spray there was no reproducible results, and further analysis indicated the presence of inclusions of manganese sulfide (MnS) damaging the oxidized layer. We calculated the severity level of the samples according to ASTM E-45 and this value was related with the time of corrosion resistance in salt spray test. If the level of severity of the 1045 steel is less than 2, one can replace the application of the industrial hard chromium by nitriding and post-oxidizing plasma process proposed, in regard to corrosion resistance.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológicopt_BR
dc.language.isoptpt_BR
dc.subjectAço - Corrosãopt_BR
dc.subjectLigas (Metalurgia)pt_BR
dc.subjectMetais - Oxidaçãopt_BR
dc.titleTratamento termoquímico assistido a plasma para incremento da resistência à corrosão de aço-carbonopt_BR
dc.typeDissertaçãopt_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.advisor.latteshttp://lattes.cnpq.br/1605939167235283pt_BR
mtd2-br.author.lattesTOMIELLO, S. S.pt_BR
mtd2-br.program.namePrograma de Pós-Graduação em Materiaispt_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples