Show simple item record

dc.contributor.advisorEly, Mariana Roesch
dc.contributor.authorLima, Luiza Felippi de
dc.contributor.otherSinnecker, João Paulo
dc.contributor.otherSilveira, Lucimeire Antonelli da
dc.contributor.otherSilva, Sidnei Moura e
dc.date.accessioned2024-09-03T13:42:24Z
dc.date.available2024-09-03T13:42:24Z
dc.date.issued2024-09-03
dc.date.submitted2024-07-24
dc.identifier.urihttps://repositorio.ucs.br/11338/13739
dc.descriptionBiossensores magnetoelásticos pertencem à classe dos sensores mássicos e seu princípio de funcionamento é baseado na variação da frequência fundamental de ressonância. Esses biossensores destacam-se pela capacidade de detecção específica de patógenos mediante funcionalização estratégica de sua superfície. Nesta tese foi desenvolvido um biossensor magnetoelástico para detecção de Sars-CoV-2. Foram avaliados fatores extrínsecos que influenciam na sensitividade dos sensores magnetoelásticos, e.g. a influência da temperatura de operação, campo magnético aplicado, tratamentos térmicos e ambiente corrosivo. Um suporte de alumínio foi empregado como dissipador de calor para evitar variações de frequência de ressonância provenientes do auto aquecimento do sistema, e uma fonte de corrente de polarização com estabilidade do campo de 0,01% foi utilizada para eliminar os efeitos provenientes das variações de corrente, garantindo que as variações de frequência de ressonância sejam exclusivamente provenientes de aumento de massa. A aplicação de tratamento térmico antes e depois do processo de revestimento resultou em melhorias na homogeneidade de resposta dos sensores, além do aumento na resistência à corrosão. A superfície do sensor foi funcionalizada para torná-lo específico para detecção da proteína recombinante de Sars-CoV-2. A imobilização dos agentes de bioreconhecimento na superfície do sensor foi confirmada pela técnica de ATR-FTIR e a utilização de AuNPs, para amplificar o sinal de resposta, permitiu a realização da detecção da proteína recombinante do Sars-CoV-2. Os biossensores utilizados neste trabalho apresentaram uma sensitividade de massa de 196 Hz/µg. Alternativas para melhorar a sensitividade de massa do biossensor foram avaliadas através de simulações computacionais dos modos de vibração dos sensores, bem como a resposta da variação de frequência em função da posição e quantidade de massa carregada na superfície. A partir dos resultados obtidos foi possível realizar a funcionalização controlada da superfície do biossensor com o objetivo de ampliar o sinal da resposta levando em consideração apenas as regiões de maior intensidade de vibração e eliminando os pontos cegos, nos quais a variação de frequência de ressonância devido a massa aderida é praticamente nula. Em síntese, foi desenvolvido e otimizado um biossensor magnetoelástico para a detecção específica da proteína recombinante do Sars-CoV-2. Além de confirmar a eficácia da funcionalização da superfície do sensor e a amplificação do sinal por AuNPs, este trabalho destacou a importância de fatores extrínsecos, na sensitividade do dispositivo. As simulações computacionais permitiram a otimização da distribuição de massa na superfície do sensor, maximizando a sensitividade e eliminando pontos cegos. Esses avanços, permitem a utilização do biossensor com maior precisão e confiabilidade, consolidando-se como uma ferramenta promissora para aplicações diagnósticas na detecção de vírus. [resumo fornecidos pelo autor]pt_BR
dc.description.abstractMagnetoelastic biosensors, categorized as mass sensors, operate by detecting variations in the fundamental resonance frequency. Their standout feature lies in their targeted pathogen detection capability, achieved through precise surface functionalization. In this thesis, a magnetoelastic biosensor was developed to detect Sars-CoV-2. Extrinsic factors influencing the sensitivity of magnetoelastic sensors were evaluated, e.g. the influence of operating temperature, applied magnetic field, thermal treatments, and corrosive environment. A support made of aluminum was used as a heat sink to prevent resonance frequency shifts due to self-heating, and a polarization bias current source with field stability of 0.01% was implemented to eliminate the effects of current variations. This ensured that any changes in resonance frequency were solely attributable to an increase in mass. Applying thermal treatment before and after the coating process improved the homogeneity of the sensor response and increased the corrosion resistance. The sensor's surface was functionalized to make it specific for detecting the recombinant Sars-CoV-2 protein. ATR-FTIR confirmed the immobilization of biorecognition agents on the sensor surface. Using AuNPs to amplify the response signal allowed the detection of the Sars-CoV-2 recombinant protein. The biosensors used in this work present a mass sensitivity of 196 Hz/µg. Alternatives to improve the biosensor's mass sensitivity were evaluated through computational simulations of the sensors' vibration modes, as well as the frequency variation response as a function of the position and amount of mass loaded on the surface. From the results obtained, it was possible to carry out controlled functionalization of the biosensor surface to expand the response signal, taking into account only the regions with the highest vibration intensity and eliminating the blind spots in which the resonance frequency variation due to the adhered mass is practically zero. In summary, a magnetoelastic biosensor was developed and optimized for the specific detection of the recombinant Sars-CoV-2 protein. In addition to confirming the efficacy of the sensor surface functionalization and signal amplification using AuNPs, this work highlighted the importance of extrinsic factors on the device's sensitivity. Computational simulations allowed for the optimization of mass distribution on the sensor surface, maximizing sensitivity and eliminating blind spots. These advancements enable the biosensor to be used with greater precision and reliability, establishing it as a promising tool for diagnostic applications in virus detection. [resumo fornecidos pelo autor]en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPESpt_BR
dc.language.isoenpt_BR
dc.language.isoptpt_BR
dc.subjectBiossensorespt_BR
dc.subjectCOVID-19pt_BR
dc.subjectBiotecnologiapt_BR
dc.subjectMagnetostricçãopt_BR
dc.subjectBiosensorsen
dc.subjectCOVID-19en
dc.subjectBiotechnologyen
dc.subjectMagnetostrictionen
dc.titleBiossensor magnetoelástico para diagnóstico de Sars-Cov-2pt_BR
dc.typeTesept_BR
mtd2-br.advisor.instituationUniversidade de Caxias do Sulpt_BR
mtd2-br.advisor.latteshttps://lattes.cnpq.br/1586983656057210pt_BR
mtd2-br.author.lattesLIMA, L. F.pt_BR
mtd2-br.program.nameDoutorado em Biotecnologiapt_BR
mtd2-br.contributor.coorientadorAguzzoli, Cesar
mtd2-br.campusCampus Universitário de Caxias do Sulpt_BR


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record